Hi developers,
thanks for your very useful tool.
I have two .mcool matrices with several resolutions which I want to compare. hicCorrectMatrix diagnostic_plot tells me, that at 1MB resolution, matrix A has around 27,000 counts per bin and matrix B has around 10,000. At 100 kb resolution, matrix A has around 2,700 counts and matrix B has around 1,000. That fits very well.
As I want to compare them, I normalize them together with hicNormalize --normalize smallest. For the 1 MB resolution, all is fine (around 10,000 counts for both matrices). But I get a weird output for the 100 kb resolution: matrix A has only around 100 counts while matrix B has the expected 1,000 counts. I checked my code to be sure not mixing up resolutions.
Could that result from using .mcool files? Thanks for your suggestions.
Best,